taco smart plus recirculating pump


By removing the ironized hardness from the water, there should be less of a chance of galvanic reaction between the water and the stainless steel volute used in this pump. Plug the circulator 120V line cord into the 3 prong receptacle on the face of the SmartPlug. I wonder what the results would be with the switch in the other position. Call for Pricing. Thanks for you awesome post! does it read the rise in temperature during the “pulse” as a way to self-calibrate such that putting a stead load on the sensor terminals would defeat?) This was a great investment as well. ;), The temperature graph – what’s the scale of the y-axis? View Cart. I rather doubt that even a tank less water heater could outperform this unit. Can you tell me if the the pump has been working out for you as described by pump brochure? It’s designed to learn your schedule, to avoid energy losses associated with pumps that run 24 hours a day, due to both the electrical energy used, and the lost heat in the loop when there is no hot water demand. I prefer the pulse mode to continuous. However I as i am unfamiliar with that particular heater I would suggest you reach out to Rheem. My issue is that it NEVER has gone out of “pulse” mode. The smart mode ( week of learning followed by a week of similar activity is a disaster for me) the 2.5 minute pump followed by 10 doesn’t seem to keep water hot all the way through the pipes. Taco's SmartPlus-e system delivers instant hot water comfort and savings to systems with a dedicated hot water return line. This Taco Smart Plus recirculating pump may well be the best plumbing performance upgrade a home owner can install. I don’t really have any more thoughts on this, other than that the thing just doens’t seem to work as advertised. edit: Now that I’ve RTFM’d again, I see that power loss causes the pump to start its learning cycle all over again, and “pulse” for a week while it learns. Watts Premier Instant Hot Water Recirculating Pump System with Built-In Timer Taco 006-B4 Bronze Circulator Pump 3/4-Inch Sweat Taco 006-IQST4 Bronze Smart Plus 3/4-Inch SS FPT … The SmartPlus circulator has a mode select toggle switch on the electronic control board that allows for 2 operation modes. Check back next Wednesday, I guess. Cheers! To see availability for this product, Create an Account. My lines are all insulated but I was using 1600 Kw/month (instead of the tanks rated 5160/year). The Taco Hot-LinkPlus-eTMSystem for Domestic Hot Water recirculation ensures instant hot water comfort at showers and faucets. Login. I removed the sensor from the supply pipe (just let it dangle) for over a week, assuming that would kick it into “vacation mode.” It didn’t. At least the pump’s “pulse” operation (running 2.5 mins on, 10 mins off) cuts down on electrical energy use compared to a pump that runs constantly. It ran much more frequently than I would like – erring on the side of hot water availability, I guess, but I had hoped for more efficiency. Notify me of follow-up comments by email. Thus you need to direct your question to Rheem the manufacturer of the heater. How is the Taco SmartPlus recirc pump working in my house? 7. We not only got hot water much faster but we also got more volume at greater pressure. Just plug the circulator … This is a big building with the return recirculating temps coming back at 101-109 F. We just got the solar data logger on line and I noticed that during the day that the storage water bumps up the temperature of the water going into the main DHW tank, so the boiler doesn’t fire during the day. This will easily pump water throughout a three story home. The green POWER LED will illuminate. To answer this question you really need to reverse it. Following the link, I downloaded the manual for the Taco device @ http://www.taco-hvac.com/uploads/FileLibrary/102-475.pdf. The resulting and repeated short cycling will destroy the heater. SmartPlug will turn the circulator … The water in the tank is around 120F/50C or a bit higher, which suffices, I think. Product Details. So I had to find out, “is our smart pump learning?”  And so far, I have to say it’s not. Taco 006-IQB4 - 006 Bronze Smart Plus, 3/4" Sweat, 1/40 HP - SmartPlus can save up to 12,000 gallons of water each year and reduce electrical consumption up to 94% when compared to traditional continuous run domestic hot water recirculation pumps. I’m surprised that the 2.5 minute pulsing doesn’t work, though – is your hot water run (and return piping) insulated? The Taco SmartPlus hot water recirculation pump is designed to push domestic hot water around a recirculation loop, so that hot water is at the taps when you want it, saving time as well as … I have a long run for my water and am only in my house every other week. The smart plug will stay on pulse mode and then I’m able to set it for my hot water usage. That ends up using about 8kWh/month. I liked the purported high-tech/smart nature of this pump, and wanted to give it a try. Interesting post and information. Already a customer? The patented SmartPlug ® Instant Hot Water Control lets you upgrade any existing hot water recirculation pump with a power cord to “Smart” operation. I reported all this to Taco and they told me to return the unit for a replacement. Click to share on Twitter (Opens in new window), Click to share on Facebook (Opens in new window), Click to share on Google+ (Opens in new window). I had somehow glossed over the fact that a power loss causes it to go back into learning mode for a week. During the same time period, here’s the temperature on the water heater output (Ignore the fact that it says input, I mislabeled it) :). Added to your cart. To see pricing and availability for this product, Create an Account. Hopefully less wear and tear on pipes. Thanks. Taco … At least in my household, this didn’t work – we had so many periods of use that it ran almost all the time in “smart mode” so in the end, I simply put it on a timer, I’m afraid. As a result some units are built with or installed with small amounts of buffer storage so that the hot water in the storage tank can be circulated without firing the appliance. Hampton Bay Hampton Assembled 36x30x12 in. Its got a phone app that is more convenient than going out to my utility room. The additional features that this unit offers will save even more money but not continuing to draw water from the hot water heater once the Taco Smart Plus detects that there is no call for hot water over a few days the hot water goes in to a standby mode until the Family comes back from a vacation or business trip. Type: Smart Plus. Smart Plus Hot Water Recirculation. Please call us at: 1-800-HOME-DEPOT (1-800-466-3337), Please enter in your email address in the following format: you@domain.com. How the SmartPlus Circulator … Just a thought; the only down side is we have to wait ~1 minute for water but no wasted water down the drain. The question is not can this or any other re-circulation pump be used with a tankless heater. Pump Accessories. 80, 150, 220 Assorted Grits Advanced Sanding Sheets (6-Pack), Rust-Oleum Specialty 1 qt. Why not just use an on demand switch (z-wave, insteon, etc) in each bathroom to turn the pump on for a few minutes when you need it? A recent energy audit showed that my circulator was going on in pulse cycle 24 hrs a day sucking cooler water into my tank which then turned on my tank heater. Pulse mode: when set for pulse mode, the SmartPlus circulator will run for 150 seconds every 10 minutes to maintain hot water at all fixtures, Smart mode when set for smart mode, the circulator will run in pulse mode as above for the first 7 days; during the first 7 days, the SmartPlus will monitor and record the homes hot water usage pattern; for the next 7 days, the SmartPlus will use the preceding week’s usage pattern to cycle the pump; this process will be repeated every 7 days, Vacation function - after 36 hours of inactivity the pump will automatically turn off and remain off until hot water usage is detected again, Exercise function - while in vacation mode the pump will cycle on once every 7 days and run for 10 seconds to prevent any corrosion or scale buildup, Unique replaceable cartridge design-field serviceable, Save up to 12,000 gallons of water per year, Automatically learns your weekly pattern of hot water usage. In theory the pump works by detecting a sustained rise in temp, indicating a hot water draw. You are always going to find this model being great when it comes to its working capability. I’ve put it on manual mode and attached a timer. Sometimes the constant start stop can destroy the heater, conversely sometimes the pump lacks the flow rate to cause the heater to turn on. The big dip last night was an unnamed person using all of the hot water, so the output temp dropped due to that. It looks like since I bought mine Taco has come out with a new revision of the control board which among other things has a memory or battery in case of a power failure, so that might help a little… I’d love your thoughts on this. Taco 006-IQBC7-1IFC Bronze Smart Plus 1/2-Inch Sweat with Line Cord, Electronic Smart … Also if I leave town and forget to turn it off I can do so remotely. It’s in Degrees F, but it’s an uncalibrated temp sensor, not terribly well coupled to the outside of a pipe – so I think it reads quite low. I have to admit, looking at the graph doesn’t make me feel any smarter than the pump. The Taco Smart Control has been installed for a week and we had to unplug it to reroute the cord, so we’ll wait another few days to see if this thing works. And in my fiddly nature, I’ve dropped power to i.e. Part #T006IQBC4 | Manufacturer Part #006-IQBC4. Head is the height when you are fighting gravity. I’m on the verge of disabling its smarts, to be honest, and just putting it on an outlet timer. So I need to leave it unmolested for a week, and see how it does. The thing should work. Instead the question is can re-circulation be used on your water heater. But that’s not what it does; it’s 2.5 mins on, 10 mins off. A dedicated hot water recirculation … By way of background, I have worked for a Rheem/Ruud distributor for the last forty years, so I am familiar with them. The 00e Series - 006e3 is an infinitely variable fixed speed, high-efficiency wet rotor circulator with an ECM permanent magnet motor. All and all with the Wemo timer and the pulse mode the pump is only running about 3 hours a day. (In this case, it runs 5on/10off.) The SmartPlus circulator has a mode select toggle switch on the electronic control board that allows for 2 operation modes. Old thread, but very helpful. 2.) © 2000-2020 Home Depot Product Authority, LLC. So I think it’s in smart mode, it’s just not being very smart yet! This pump had an instant effect on getting us hot water within mere seconds rather than Minutes as it was previously performing. Already a customer? Smart control that learns homeowners hot water usage pattern; Sensor included; Learns to cycle pump … Unfortunately I dropped power to set up the monitoring, and dropped it again today before I opened it up to check the switch. I am asking because here in Germany it seems everybody urges you to keep the hot water tank above 60° to avoid legionella growth: The Taco Smart Plus hot water recirculation pump more than met our expectations. In a circulation system the weight of the water you are pumping up is offset by the weight of the water coming down. I can see where a week home / week gone schedule would really not work. I promise to leave it alone for a week, and report back! All Rights Reserved. It is the reason you get the … The question is not can this pump or any other pump be used with a specific water heater. I went that route and saved about a lot of $ in gas and electric bills with our reciruculation system vs the 15 min on/off timer on the grundfos pump we have (granted your pump sounds much fancier)…. Use of this site is subject to certain Terms Of Use. This process will be repeated every … SmartPlus can save up to 12,000 Gal. The SmartPlus pump is supposed to be “smart” in the sense that it uses a temperature sensor on the output of your water heater to learn when you use hot water, and adjust its run schedule accordingly. The advantage to the Wemo is I can easily switch it off and on for hot water outside of my usual usage times. There is no head when you are using a re circulation pump. I would check out the installation manual for your heater to see what it says about this before proceeding. Smart Mode learns household hot water usage patterns, running the circulator only when hot water is needed; Pulse Mode cycles the circulator on and off maintaining hot water at all fixtures at all times; Vacation Mode turns the circulator … If the controller doesn’t figure out the demand, we’ll put it in the ‘Pulse mode” and that will alone save 50% in pump run time and a lot of heat loss. It’s too bad, I really wanted this thing to work as advertised but it just wasn’t smart enough to be better than a timer, in my opinion. x 11 in. The TacoGenie is a small, silent pump that attaches to the hot and cold water lines in the cabinet under the most remote kitchen or bath fixture in the home. The question is can your tankless heater and or the way it is piped be used with a re-circulation pump. The rise later in the afternoon I can’t explain. By recirculating “cooled” hot water back to the water heater, the wait for hot water is reduced to seconds. I got the Taco Smartplug for it that basically turned it into a Smart Pump and piggybacked that onto a Wemo wifi timer. ... Taco 006-IQB4 Bronze Smart Plus 3/4-Inch Sweat with Line Cord and Electronic Smart Timer. This is what I did with the circ pump on my plumbing. I tried searching the topic on line but nothing relevant came up. Mine is on a Wemo now too. Your email address will not be published. If it could smarten up a bit, it’d use less! The new one arrived yesterday, so I’ll have to wait a week to see if this one works. By recirculating "cooled" hot water back to the … http://www.taco-hvac.com/uploads/FileLibrary/102-475.pdf, https://en.wikipedia.org/wiki/Legionella#Legionella_control. I get about a 12 degree delta from HW calls to non-calls (110 degrees to 98 degrees–and this is in the ten minutes between pulses. :), But – thanks for pointing me to the manual again. If nothing else, I’d like the ability to “learn” but also set time periods when it should simply never run; say, 1am to 6am. NOTE: The circulator must be a prop - erly grounded 120V pump. I was intrigued by your post. It is perfect for hot water recirculation and hydronic heating … of water each year and reduce electrical consumption up to 94% when compared to traditional continuous run domestic hot water recirculation pumps. A Taco SmartPlus circulator pump is installed on the hot water supply line, or on the hot water return line, and controlled by the SmartPlus electronic control board. Taco SPE-1 - SmartPlus-e ECM High-Efficiency Instant Hot Water System - Perfect for systems with a tank water heater and dedicated hot water return line, the SmartPlus-e combines the high-efficiency of the 006e3 ECM circulator … the other thing that’s kind of funny: it says that it runs for “150 seconds every 10 minutes” – which would imply 2.5 mins on, 7.5 mins off. Perhaps you could explain it to me and then I will be able to offer you some help. So perhaps I’m not giving it a fair shake. I will be adding a recirculating pump soon and was thinking about using a raspberry pi to control the pump, I’ve thought about that as well; I do think I could probably do a better job than the pump’s firmware. There was a rise around 7am; that was a shower this morning. My remotes for my d’mand system are all dead and I wanted to implement exactly what you are talking about but no one I’ve asked has been able to help. The Taco 008 SmartPlus® is designed to increase hot water comfort while conserving water and energy. However I can tell you that with tank heaters I have never had an issue. Wouldn’t seem that hard to get it right. It is just spinning the water around in a big circle. The TacoGenie delivers hot water to faucets. Stainless Steel Portable Folding Utility Table, 3M Pro Grade Precision 9 in. Yep! How the SmartPlus … If this new one behaves like the first one, I’m really stuck for an explanation. Some water heaters will be destroyed by the frequent on and off short cycling and others will not turn on with based on the very slow flow rates used in these pumps. ft. White Top Load Washing Machine with Stainless Steel Basket, SmartPlus 1/25 HP Non-Submersible Hot Water Recirculation Pump in Stainless Steel, TacoGenie 1/40 HP Hot Water Recirculating Pump with Undersink Kit, TacoGenie 1/25 HP Hot Water Recirculating Pump with Undersink Kit. SmartPlug® Instant Hot Water Control | Improve Performance of Standard Hot Water Recirculation Pump The SmartPlug® is an instant hot water recirculation control that upgrades any existing hot water recirculation system to an energy-saving smart system. what is the duration slope. I would welcome you to give me a call if you would like to talk about this some more but I am baffled based on the information you have given so fare. Sometimes this pump does, because it runs for 1 hour either side of a “use” and that tends to make it run more than I’d like, and spill over to hours when it has absolutely no need to run …. FWIW, the graphs above are from xively.com, with data pushed there from a Brultech ECM-1240 electricity monitor and Matthew Wall’s mtools scripts, as well as temperature data fed from an Electric Imp. If you look at the docs for it, they explain how it is designed to sense hot water use, learn the schedule, and automatically run only at those times. When running, it uses 55W in my system. https://en.wikipedia.org/wiki/Legionella#Legionella_control. I’ve been going around and around with Taco having to do with their subsequent product, the SmartPlug. Like with a sump pump you want to know the curve based on how much water it will lift at different heights up until the point it dead heads. I could revert to a remote switch with this one too, actually, if it turns out to not be so smart. A yellow LED indicates which mode is selected. Heat pumps, yes, but not tank type heaters. All the little sawtooth bumps are due to the pump circulating water, and drawing up more heat. I gave up on its claimed ability to learn our schedule.). Move the sensor further downstream from the DHW. Wondered if I had a check valve to prevent thermic migration (I do.) The Smart Recirculation Control is an "On-Demand' smart hot water recirculating pump controller for homes with a dedicated recirculation loop (If you don't have a dedicated recirculation loop check out our Smart Thermostatic Control) and a tank water heater (If you don't have a tank water heater check out our Smart … The Taco SmartPlus hot water recirculation pump is designed to push domestic hot water around a recirculation loop, so that hot water is at the taps when you want it, saving time as well as water down the drain while you wait. Chris 978 651 3301, The question is misplaced. So way before the system separates into hot, cold and for the purpose of this discussion the recirculation line. It’s the only real review I could find online. but they declined. per year. My hot water circulating pump used to be on a timer and was not usually on when I got up in the morning. Circulator Pumps; End Suction Pumps; Header Pumps; High Efficiency ECM; Hot Water Recirculation System; Horizontal In-Line Pumps; In-Line Pumps; Split Case Double Suction; Vertical In-Line Pumps… Above is a graph of the electricity used on a circuit dedicated to the water heater and the recirc pump. 6. You will need Adobe® Acrobat® Reader to view PDF documents. “Pulse” or “Smart” mode can be selected using the toggle switch located on the capacitor base mounted electronic control board. We are not a complicated household (two people and very predictable schedules.) When I received this product it appeared to be either tampered with, or of shoddy workmanship. Can you tell me a little bit about your setup. If circulator is equipped with a timer, turn the switch to full ON position. set up the monitoring. That's a good thing. Well, if that’s the case, it’s too bad. Part #TSPE1 | Item #7559528 | Manufacturer Part #SPE-1. :) Oh well.). Taco. A Taco SmartPlus circulator pump is installed on the hot water supply line, or on the hot water return line, and controlled by the SmartPlus electronic control board. Installing recirculation on an instantaneous heater can be problematic. I tried to get tech support to give me some programming parameters (i.e. This makes recirculation pretty straight forward. (I had trouble w/ the check valve issue at one point too, and had a big argument with the plumber about why one was needed o_O). Easy to install, you have to have a loop plumped in your hot water line for this to work, very quite. The Taco Smart Plus hot water recirculation pump more than met our expectations. But I have never heard the term heat lock used in reference to a tank type hot water heater. Starting at. The problems have always been with instantaneous heaters. Local store prices may vary from those displayed. SmartPlus® 1/40 hp 115V Circulator Pump. The thing has won awards, for God’s sake. Fittings/Flanges; Multi-Purpose Valve; Pressure Control; Suction Diffuser; Timer & Aquastat; Pumps & Circulators. I am getting ready to install this pump on a recirculating loop. Your email address will not be published. White Tub and Tile Refinishing Kit, GE 4.2 cu. It saves thousands of gallons of water per year by supplying fresh hot water to the fixtures while returning the “cooled” hot water back to the water heater through the cold water … As you can see, it’s got activity at all hours of the day. Now, with Taco's smart technology, the Smart Plug is constantly … (The weird modulation is because the pump runs 2.5 mins on, 10 mins off, and the datapoint averaging wasn’t lined up with 12.5 minute periodicity…). Description The Taco SmartPlus circulator is designed to deliver instant hot water comfort and convenience while conserving water and energy. Many tankless water heaters can not be used with re-circulation pumps because every time the re circulation pump creates flow it will cause the heater to come on. I even jumpered a 10K resistor across the sensor terminals which should have guaranteed a rock-solid 77 degree equivalent, pretty sure that that would trigger “vacation mode.” It didn’t. If you feel I am missing something you are welcome to give me a call. It probably does use a bit more energy than your switch arrangement, but so far I like the convenience of the thing. Switching to the POS Taco circulator and will report back on the results. Yep, it does have those two modes – but I opened it up and confirmed that the switch is in the “smart” position.